Patio Paving and Sub-Base Calculator

Estimate paving, MOT Type 1 sub-base, sharp sand and cement for a new patio laid on a full mortar bed.

Project Inputs UK Metric
Patio Sub-Base & Bedding
Paving (inc. 5% cuts)
25.2 m²
Calculated with 5% paving wastage, MOT Type 1 compacted at 2.1 t/m³, and a 40mm wet mortar bed at 4:1.
Patio Area
24.00 m²
Paving (inc. 5% cuts)
25.2 m²
MOT Type 1 Sub-Base
5.04 tonnes
Sharp Sand for 40mm Bed
1.23 tonnes
Cement (25kg bags, 4:1 bed)
12 bags
  • Porcelain needs a slurry primer on the back of each slab to bond to the bed.
  • Keep the finished patio at least 150mm below the damp-proof course.

How to Use This Calculator

  1. Enter the patio length and width.
  2. Enter the compacted sub-base depth (100mm for foot traffic, 150mm or more for vehicles).
  3. Choose porcelain or natural sandstone.

Measuring and Common Mistakes

Mark out the proposed perimeter of your paved area using pegs, string lines, and a builder's square to ensure corners are set accurately. Measure the length and width along the perimeter. Recommended sub-base depth for domestic pedestrian paving is a minimum of 100 mm of compacted MOT Type 1 crushed stone aggregate, followed by a 30 mm to 50 mm mortar bedding layer.

Common mistakes in patio groundwork planning include:

  • Ordering MOT Type 1 based on uncompacted loose volume; crushed stone settles and compacts down by 20% to 25% when compacted with a heavy vibrating plate.
  • Laying porcelain slabs on dry sand or without a slurry primer; external porcelain tiles have near-zero porosity and will not bond to mortar without polymer slurry priming.
  • Failing to establish a minimum 1:60 to 1:80 drainage fall away from the house, or laying patio surface levels less than 150 mm below the property damp-proof course (DPC).

This calculator covers domestic pedestrian garden patios and footpaths. It is not suitable for vehicular driveways, which require deeper engineered sub-bases (minimum 150 mm to 200 mm) and concrete or permeable block paving. Under England planning rules, paving more than 5 square metres in front gardens requires planning permission unless the surface is permeable or drains to an adjacent lawn or border.

Planning & Construction Reference

How the estimate works

Paving = area + 5% for cuts. Sub-base tonnes = area × depth × 2.1 t/m³ compacted. The mortar bed is taken as 40mm of a 4:1 sharp-sand:cement mix.

Worked example (the default inputs)

A 6m × 4m patio needs 25.2 m² of paving, about 5 tonnes of MOT Type 1 at 100mm, 1.2 tonnes of sharp sand and 12 bags of cement.

Tips

  • Keep the finished surface at least 150mm below the damp-proof course of the house.
  • Compact the sub-base in layers of 50–75mm with a plate compactor.
  • Use a jointing compound or slurry grout that suits your slab type.

Sources

Guidance on permeable surfacing of front gardens.

Frequently Asked Questions

Do I need planning permission for a patio?

Usually not in a back garden. Paving more than 5 m² of a front garden in England needs permission unless it is permeable or drains to a lawn or border.

How much fall should a patio have?

About 1 in 60 to 1 in 80 away from the house, so water does not pond against the wall.

Can I lay porcelain on a sand bed?

No. Outdoor porcelain is non-porous, so it needs a full mortar bed and a slurry primer on the back of each slab to bond.

Related Guides

Front gardens: in England, paving more than 5 m² of a front garden with an impermeable surface that drains onto the road needs planning permission. Permeable paving, or directing water to a lawn or border, avoids this.